Search results for "beam [electron]"
showing 10 items of 433 documents
Is periapical surgery follow-up with only two-dimensional radiographs reliable? A retrospective cohort type sensitivity study
2021
Background Two-dimensional (2D) radiographic techniques are commonly used for assessing lesion prognosis after endodontic surgery. The present retrospective cohort study analyzes the sensitivity and ability of different radiographic techniques in obtaining area and volume measurements of periapical lesions. Material and Methods Preoperative and follow-up (6-48 months) periapical and panoramic radiographs (index test) and cone-beam computed tomography (CBCT) images (reference standard) were selected from an endodontic microsurgery database. Sensitivity was analyzed independently by two examiners. The areas of the 2D radiographic images and CBCT volumes were studied using Itk-Snap software an…
Radiation dose in non-dental cone beam CT applications: a systematic review.
2018
Background: Radiation-induced health risks are broadly questioned in the literature. As cone beam computed tomography (CBCT) is increasingly used in non-dental examinations, its effective dose needs to be known. This study aimed to review the published evidence on effective dose of non-dental CBCT for diagnostic use by focusing on dosimetry system used to estimate dose. Materials and methods: A systematic review of the literature was performed on 12 November 2017. All the literature up to this date was included. The PubMed and web of science databases were searched. Studies were screened for inclusion based on defined inclusion and exclusion criteria according to the preferred reporting ite…
Influence of voxel size on the accuracy of linear measurements of the condyle in images of cone beam computed tomography: A pilot study
2018
Background To analyze the influence of voxel size and exposure time on the accuracy of linear measurements of the condyle. Material and methods Four macerated hemi-mandibles of pigs were scanned in nine different voxel size protocols. Three-dimensional models of the condyle were generated in order to establish a comparison between linear measurements obtained with each voxel protocol and those obtained with a caliper (gold standard). The comparison between the protocols was performed considering the average of the two measurements of the condyle in the latero-medial (LM) and antero-posterior (AP) axes and also through repeated measurement ANOVA with rank transformation. The level of signifi…
Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study
2017
AbstractThe accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superim…
Role of cone-beam computed tomography (CBCT) in diagnosis and treatment planning of two-rooted maxillary lateral incisor with palatogingival groove. …
2020
Background: The embryonic root groove is an anatomical abnormality that starts in the cingulum and extends longitudinally down the long axis root towards the apex. This developmental anomaly is more frequently reported in maxillary lateral incisors. Gu YC in 2011 established three types of radicular grooves depending on its severity. According to this classification, type III presents a greater diagnostic and therapeutic complexity. The prevalence of palatogingival grooves in maxillary lateral incisors ranges from 1.9 to 14%. This case report provides valuable information about the diagnosis and treatment plan of palatogingival grooves with Cone-beam computed tomography (CBCT) scan. Case re…
Auto calibration of a cone-beam-CT
2012
Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form l…
State of the art and clinical recommendations in periapical implant lesions. 9th Mozo-Grau Ticare Conference in Quintanilla, Spain.
2016
This manuscript summarizes the statements and clinical recommendations in periapical implant lesions, as per the state of the art and expert opinion agreement among the participants in the 9th Mozo-Grau Conference 2016 held in Quintanilla (Valladolid, Spain). The current status of the concept, frequency, etiology, diagnosis, clinical classification, surgical procedure and prognosis are described. If following implant placement localized pain develops in the periapical area, with or without radiographic changes, the diagnosis of periapical implant lesion should be suspected. It is important to monitor the condition in order to identify any change in its evolution. Radiological changes in the…
Diagnosis of simulated condylar bone defects using panoramic radiography, spiral tomography and cone-beam computed tomography: A comparison study.
2014
Objectives: Radiographic examination is one of the most important parts of the clinical assessment routine for temporomandibular disorders. The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography(CBCT) with panoramic radiography and spiral computed tomography for the detection of the simulated mandibular condyle bone lesions. Study Design: The sample consisted of 10 TMJs from 5 dried human skulls. Simulated erosive and osteophytic lesions were created in 3 different sizes using round diamond bur and bone chips, respectively. Panoramic radiography, spiral tomography and cone-beam computed tomography were used in defect detection. Data were statistically …
Interobserver and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography
2021
Background Data regarding the inter- and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography are missing in the current literature. This study assessed the inter- and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography (CBCT). Material and Methods In 107 patients, 130 salivary glands (65 parotid and 65 submandibular) with clinical signs of obstruction were assessed by four independent observers; 2 residents OMFS and 2 experienced OMFS. The observers analyzed the CBCT images and determined the absence or presence of one or more salivary stones in the affected gland. This proc…
Symmetry of root and root canal morphology of mandibular incisors: A cone-beam computed tomography study
2019
Background Aim of this study was to analyze the root canal configuration in mandibular central and lateral incisors in vivo using cone-beam computed tomography (CBCT) imaging. Material and methods A total of 487 mandibular central incisors and 491 mandibular lateral incisors from 250 patients were examined using CBCT imaging, previously taken for diagnosis and treatment. The number of roots, root canal system configuration, presence of apical confluences, distance between confluences and radiographic root end, symmetry between left and right elements were recorded and statistically analyzed. Results All the examined teeth presented only one root. No significant differences were found betwee…